Being a quality centric organization, we are offering high quality Air Aftercooler. Air cooled compressed air after coolers cools the compressed air with atmospheric air. The compressed air is cooled to approximately 9oC above ambient temperature. A sufficient capacity after cooler can take upto 80% of the moisture present in the compressed air.
Sizing Notes, Recommendations are based on the following
- Heat Removal : After cooler = Compressor horsepower x 1.15 ( motor service factor ) x .17 (this assumes 17% of input horsepower is rejected to heat).
- 15oF Approach Temperature : Compressor air outlet temperature - ambient air temperature.
- Temperatures : Ambient Air Temperature + 15oF = Compressed Air Outlet Temperature.
- Flows : Compressor Horsepower x 4.5 = SCFM Air Flow.
- Air flow rates are based on less than a 4 PSI pressure drop @ 100 PSI operating & 100oF ambient and 50% relative humidity.
SpecificationsRatings
- Maximum working pressure : 250psi
- Maximum working temperature : 250oF
Materials
- Cooler : Aluminum
- Shroud : Powder Painted Steel.
- Fan guard : Zinc Plated Steel.
- Fan Blade : Polypropylene Blades Aluminum Hub.
- Mounting brackets : Powder Painted Steel.
Place of Origin | Not Given |
Minimum Order Quantity | Not Given |
Supply Ability | Not Given |
Packaging Details | Not Given |
Delivery Details | Not Given |